The World's First Point-Of-Care CO-Oximeter

The AVOXimeter 4000 provides a fast, accurate assessment of patient oxygenation at the bedside. The AVOXimeter’s patented state-of-the-art optics yield accurate measurements of oxy-, carboxy-, and met-hemoglobin as well as total hemoglobin. When used in combination with a blood gas analyzer, the AVOXimeter 4000 gives a comprehensive and complete assessment of the patient’s oxygenation status.

The AVOXimeter 4000 is a portable, battery-powered system designed to meet the accuracy demands of today’s lab managers yet is easy enough for point-of-care, bedside testing. The AVOXimeter 4000 requires no sample preparation, needs only 50 μl of blood, and utilizes inexpensive disposable cuvettes.

Results are obtained in less than 10 seconds. Comprehensive data management, quality control, and readily available proficiency-testing materials make regulatory compliance quick and easy.

System Specifications

Measurements and Operating Ranges
Total Hemoglobin (tHb)   4 to 25 g/dl
Oxyhemoglobin (O2Hb)   0 to 100%
Carboxyhemoglobin (COHb)   0 to 75%
Methemoglobin (MetHb)   0 to 85%
Oxygen Content (O2Ct) calculated   0 to 35 ml/dl
Accuracy and Precision
       Accuracy      Precision
Total Hemoglobin (tHb) (> 10 g/dl)   ± 0.45 g/dl   ± 0.3 g/dl
(< 10 g/dl)   ± 0.35 g/dl   ± 0.3 g/dl
Oxyhemoglobin (O2Hb)   ± 1.6%   ± 0.8%
Carboxyhemoglobin (COHb)   ± 2.0%   ± 1.0%
Methemoglobin (MetHb)   ± 1.5%   ± 0.7%
Interferences
    tHb   %O2Hb   %COHb   %MetHb
Bilirubin   none   none   < 1%   < 1%
Hemolysis   none   none   < 1%   < 1%
Fetal Hemoglobin   < 0.45 g/dl   < 1%   0.06%/% HbF   < 1%
(tHb=13.5 g/dl, HbF=100%)                
Indocyanine green   < 0.45 g/dl   < 1%   < 1%   < 1%
Other Information
Sample type
  Whole blood
Sample volume   50 μl
Time per sample   less than 10 seconds
Data display   4 x 20 characters
Data storage   100 samples in non-volatile memory
Dimensions   10 x 8 x 3.75 inches
(25.4 x 20.3 x 9.5 cm)
Weight   4 lbs. (1.8 kg)
Serial port   RS 232C (DB 9 connector)
Battery   4 cell, NiCad
Battery charger   110 VAC, 220 VAC
Approvals   FCC Class A, UL 544, CE mark

US Patents 6,262,798 and 5,430,542 and Euro/UK Patent 0663070

Sample is analyzed in less than 10 seconds.
Illuminated liquid crystal display for easy reading in dim lighting.
Data are stored for later analysis or printing.
Easy menu-driven operation.
Simple data management system with security features.
Quick and easy two-point QC.